Module performance and characteristics:
With power indicator lamp
With voltmeter display and self-calibration. A more advanced voltage microprocessor is used. The error of the voltmeter is (+0.05V) and the range is 0-40V. (Note: To ensure the accuracy of the voltmeter, please ensure that the input voltage is above 4.5V.)
Touch the button to switch the input or output voltage, and have an indicator to show which voltage is being measured, and save the settings, even if the power is off and then turn on.
The voltmeter can be turned off, and it can be easily realized by touching the left button when it is not needed.
With terminal, it is easy to use without soldering iron, and retain welding connection.
The input voltage is 4.0~38V. (Input voltage must be 1.5V higher than output voltage)
The adjustable output voltage range is 1.25V~36V. (Input voltage must be 1.5V higher than output voltage)
The output current can reach 5A, which is recommended to be used within 4.5A.
The output power can reach 75W. If the output power exceeds 50W, please strengthen the heat dissipation of the chip. (that is, a small radiator must be added)
High conversion efficiency, up to 96% (efficiency is related to input, output voltage, current and voltage difference)
Working frequency: 180KHZ
Load adjustment rate S(I)<0.8%, voltage adjustment rate S(u)<0.8%.
Overheat protection and short circuit protection (but in case of accidents, try not to short circuit)
Plate Size: 6.64*3.89CM